What to do if the house began to be feltlack of oxygen, air is saturated with unpleasant odors, and surfaces in rooms are covered with condensate? Probably the reason for this - the lack of airing housing. The elimination of the indicated negative factors allows the installation of air supply ventilation units.
What is intake ventilation?
During operation of the inlet ventilationInstallation The flow of working air enters the room in several ways. Pass through the ducts integrated into the network or penetrate through street entry points. The most effective scheme of forced ventilation is a combination of elements of forced and natural exhaust systems.
Types
Depending on the scale of action, compact air handling units are divided into systems of general and local action. Consider the features of each of the solutions presented.
Local ventilation ensures air exchange is notin all rooms, but only in a separate part of the object. Most often, such solutions are resorted to, if necessary, to clean up the space in production workshops where a high concentration of harmful substances is observed.
In turn, the total air handling unit allows you to organize the flow of fresh air at the same time in all rooms, without separation of local areas for maintenance.
Design
- Fan - provides movement of the specified volumes of air in the room.
- Filter - cleans the area from dust, carcinogens.
- Silencer - allows you to reduce the overall noise level during the operation of the system.
- Heater - heats the air distributed by the fan in winter.
- Non-return valve - prevents the outflow of fresh, purified and heated air from the premises when disabling forced ventilation.
Features of choice
Determining criteria for ventilationinstallation of the supply plan - the maximum possible pressure in the system and air pressure, which the unit is capable of issuing. The electric supply unit must also be selected taking into account the working temperature range, the dimensions of the indoor unit. All the necessary parameters are calculated at the design stage.
Characteristics of the air handling unit
- Air consumption - the volume of working environment that the system is able to pump within an hour (measured in m3/hour).
- Head - the level of resistance of air ducts that the installation must overcome at a given air flow rate.
- Parameters and coolant source. A heater or hot water flowing through pipes can be used as a means for heating the air space.
- Source of cold supply. Here, the characteristics of a chiller (refrigerating machine) or a freon circuit come to the fore.
- Level of autonomy - the parameters that the installation is able to maintain in automatic mode.
Helpful Tips
Если установка приточных установок предполагает installation of the refrigeration section; in this case, the air ducts of the forced air supply system are covered with heat-insulating materials. For these purposes, practically any common means with a thickness of at least 40 mm is suitable.
In case of addition of installation watera heater, creation of double protection against freezing is required. It is advisable to install the thermostat behind the heater and the sensor measuring the temperature of the coolant.
After the installation of the supplyinstallations, it is recommended to carry out their periodic inspection and maintenance. The bulk of failures that occur in the operation of such units, is a consequence of the untimely cleaning of filters, fan balancing, checking the condition of electrical components and the efficiency of the fans.
Planning the scale of the air handling unit is extremelyIt is important to organize the correct movement of air flow. Fresh, purified air from the street should fall primarily into the living rooms (living room, bedroom, children), then move into the corridor and go to the exhaust grilles in the kitchen and in the bathrooms. The development of a well-thought-out scheme by specialists during the installation of the air handling unit eliminates the spread of polluted air and unpleasant odors throughout the premises.
Air handling unit - price
Preparing for installation
Installation of ventilation
Local settings are really small.However, despite the small size, such systems provide a significant influx of heated or cooled, purified air into the room. Inside the compact box there is a fan for air supply from the street, a cleaning filter and automatic equipment that controls the operation of devices.
For installation of a local air handling unit, the following steps are performed:
- The installation site is selected. As practice shows, the installation of such systems looks the most rational in areas where there is a large crowd of people.
- To begin with, a corresponding markup is created, after which a hole is punched in the wall.
- Forced ventilation is installed on the facade surface close to the window or balcony, as high as possible directly under the ceiling.
- After completing the opening, the installation of telescopic air ducts. Protective caps are worn on the outside of the walls.
- Finally, the entire system is installed in the assembly.
As you can see, the installation of the air handling unitdestination is not difficult. The main task is to break through a fairly solid load-bearing wall. To do this, you will have to find the necessary equipment, tools, and personal protective equipment.
If you plan to work in a high-rise building, and there is no way to reach the installation site from the outside through windows or a balcony, it is better to involve specialists in the task.