As a very successful alternative heating systems based on radiators are heated floors, which can be designed for one room, for example, a nursery or bathroom, as well as the entire building.
Need to use
This system acts as an integralcomponent of the overall heat supply system, it is autonomous, because for its arrangement it will require special preparation of the coolant before it enters the heating circuit, namely a set of pipes to be installed in the floor.
Device
Before mounting the comb for a warm floor youshould be familiar with its device. Outwardly, it resembles a whole chain of pipes, which are combined with each other in one place. In the process of arranging them are arranged in a certain order. All pipes pursue one task, which is to connect streams of hot water into one. The master must remember that there are three types of mixing, namely sequential, parallel and combined.
Thanks to impressive performance, morepreferred is a sequential type, in which the water consumption is directed to heating. During sequential mixing, the coolant using a pump comes from a heat source, which is most often the boiler. Water comes to the floor.
If you use the parallel methodconnection, then you will encounter a loss of a certain percentage of heat, since the coolant lines will be separated from each other. However, this principle is used in some homes. The main disadvantage is that the water flow, which flows through the pipes, will be non-permanent, however, the user will be able to install a two-way valve, allowing to control the entire process.
If you use the combined blend whenarrangement of the comb for a warm floor, it is possible to apply both principles of work with the transition to one of them separately. The wizard must be aware that the collector assembly configuration may vary. In the generally accepted version, the scheme consists of a valve, a circulation pump, a water supply tee, the device of the latter of which provides automation and adjustment of the process. When mounting a comb for a warm floor, a three-way regulating valve of mixing type will be used, which will be installed on two branches. The pump pumps water until the temperature reaches a certain level. After the automation enters the work, it closes the coolant access with the help of the valves, which causes the circulation to stop. If you want to independently engage in the installation of a comb for underfloor heating, such works will include equipping the system with an air duct and a drainage component.
Assembly scheme
If you decide to do installation work, thenYou should be interested in the arrangement of the collector group, which may be different. You can select pipelines, tees, circular pump, valves, as well as automation and adjustment equipment.
Choosing and installing a comb do it yourself
The reservoir model will depend on howway and in what place is the warm floor. This affects the cost and degree of safety of the equipment. The main and very vulnerable part of it is the mixing unit, since it contains heat-transfer agent with a different temperature level. During mixing, water can reach a certain temperature, which is stored in certain parameters. From the selected materials and assembly technology will depend on the correct functioning of the system, for this reason, such details as the mixing unit, thermostat or pump must be treated with special attention.
Tips for choosing a comb
After you become aware of the devicecomb for a warm floor, you need to know what to look for at the time of visiting the store. The cost of collectors for underfloor heating is influenced by the manufacture of materials. A number of models are made of brass, while other options are based on stainless steel. In addition, the price will depend on the design features and complexity of the equipment. Among the various options are the simplest, which have the smallest set of elements. However, the sale can be found equipped with additional devices devices that are responsible for protection. This may include a crane Mayevsky. Among others, a sensor monitoring and adjusting the flow of coolant, as well as the drain valve.
If the comb for a warm floor with their own handswill be installed, it is worth paying attention to especially popular equipment that has a thermoregulation unit. The latter includes a set of sensors that monitor the temperature level. The system also has other measuring devices. The presence of automation guarantees control over the distribution process, whereas at the right moment air-release valves will be involved, they will also block the flow of water. Standard options have two thermometers that save heat loss.
Board of Installation Specialist
If you will be installed comb forunderfloor heating with a pump, then you should consider the presence of several heating circuits. In this case, it is recommended to equip each with a thermoregulation device, which consists of flow sensors. An air vent, thermometer case, mixing valve and thermal head with a probe for immersion in water will be supplied with such a collector. By means of a valve, a certain amount of hot coolant will flow into the circuit, while the thermal head will be responsible for controlling the processes, excluding the appearance of faults.
The nuances of the installation
If you pondered the question of howto properly assemble the comb for a warm floor, you should be aware that you should consider the purpose of use and the area of the room. Thus, for small rooms by type of bathroom or bathroom, a plastic collector is perfect, which is devoid of a complex temperature control system. If, nevertheless, there is a need to operate flow meters, then they can be bought additionally by paying a small cost. If you will work in a volumetric room, it is recommended to use a reliable group of mixers that have a point adjustment of the temperature level. Due to this, you can achieve the most appropriate level of contour balancing.
Features of the installation
If you will install combs forunderfloor heating, the assembly scheme will allow you to perform the work correctly. With it, you will be able to assemble the system yourself by connecting successively the most important parts, namely the pipeline, the distribution unit, as well as the boiler equipment. It is recommended to begin such manipulations with the installation of a thermometer, as well as shut-off valves, the latter of which are mounted on the circuit outputs. These parts, which are responsible for adjusting the operation of the return and supply, must be included in the kit. You will need to install a distribution node, connect the pipe for drainage and supply of water, creating the possibility of connecting as needed several or one heating circuit. After the comb for a warm floor has been acquired, it will be possible to do such work yourself, without encountering special difficulties. The coupling of the elements must be carried out using compression fittings. For the fastening of some connections, masters recommend using a standard kit, which consists of a sleeve, a nut and a ring clamp. If you are faced with a problem that is expressed in the discrepancy between the diameters of the parts, then you should use adapters.
Conclusion
The installation process of the comb must assumeconnection to the distribution node of two pipes, which are responsible for the return and flow. At the next stage, the elements of the heating circuit are connected.