/ / Lemax boilers: overview, specifications, types, instructions and references

Lemax boilers: overview, specifications, types, instructions and references

Central heating in the housethe private sector can be called a luxury, so the owners of such real estate are tirelessly looking for some other ways of heating. When the village is equipped with gas, boilers become the solution to the problem. Heating equipment, which is manufactured in factories in Russia, is almost inferior in quality to what is imported to us from Europe. Modern gas equipment is functional and practical. As an example, you can consider the boilers "Lemax".

Features Overview

boilers of a mixer

If we consider a series of economical gasboilers of the company "Lemax", it can be noted that they can be single- or double-circuit. As their distinctive feature is an impressive efficiency, which reaches a mark of 90%. One can not help but note the long service life, which, with proper use of the equipment, can reach 25 years, these factors are the best proof of the successful cooperation of companies from different countries.

The Lemax boilers are equipment thatit is easy to maintain and operate, they are available for sale in a wide range and have an acceptable cost, as well as an aesthetic appearance. This equipment has a modern design, which can be called a great advantage. Any consumer of this equipment will be affordable, because the approximate cost of the boiler "Lemax-Premium" (40 V) is 35 000 rubles. The equipment of this manufacturer is highly technological, which is why the designs can compete not only with domestic but also with foreign analogues. The main rival products are boilers Baxi, "Siberia" and Navien.

Basic views

Lemax Premium Boiler

Котлы «Лемакс» выпускаются в виде напольного equipment, as well as wall installations. In the first case, the heat exchanger can be made of steel or cast iron. In the case of steel heat exchangers, such boilers operate in closed systems, but their working pressure should be 2 atmospheres. Such devices are intended for heating small apartments, as well as private houses. In the manufacturing process, the heat exchanger is coated with an anti-corrosive substance that protects the product from the negative effects of mineral oils, if there was no such protection, the product would have to be protected from salt solutions.

Technical characteristics of floor boilers with steel heat exchanger

floor boilers

The above described Lemex floor boilers canhave a power in the range of 7.5 to 60 kW. The equipment has a system of protection against overheating, interruption of the thrust, blowing up the flame, as well as the formation of soot. All this functionality ensures safe operation. The cladding elements are removable, the devices have profile fittings, and the top panel allows for maintenance and timely cleaning of the boiler. An additional function is hot water supply.

Features of floor boilers with cast-iron heat exchanger

gas boiler

The working pressure of such equipment reaches 4 bar, the boiler can be used to heat residential premises, the area of ​​which reaches 500 m2. During the manufacturing process, the heat exchanger is covered with an inhibiting solution, this prevents corrosion processes.

Technical characteristics of floor units with cast-iron heat exchanger

cauldron

Котел отопления «Лемакс», теплообменник которого made of cast iron, can have a power in the range of 16 to 50 kW. Safety is guaranteed by the availability of protection systems against interruption of traction, overheating and formation of soot. The equipment has a gas valve, which is manufactured in Italy, this addition allows you to reduce fuel consumption by up to 30%. There is a function of hot water supply in this equipment, but the efficiency is somewhat higher and is 91%.

Features of wall-mounted boilers

heating boiler

The Lemax boilers can also be wall-mounted, theyare more convenient for operation in an apartment, after all occupy less space. The pressure in the system does not exceed 3 bar, and the heated area of ​​the building can reach 240 m2. This equipment is volatile, and below youyou can get acquainted with its technical characteristics. Power indicators vary from 10 to 24 kW. The coefficient of efficiency increases to 93%, there is a function of hot water supply. Reliability is provided by the pressure valve, thermostat and frost protection.

Reviews of the floor boiler series "Premium KSG-10"

The boiler "CSG Lemax" has a steel heat exchanger.Its cost is 16 500 rubles. According to users, this device can be used in systems with natural or forced circulation of the coolant. Boilers are manufactured in accordance with quality standards, therefore have high reliability and safety. Consumers especially note the durability, this is guaranteed by the enameled anti-corrosion coating of the heat exchanger. This product has an insulation layer that protects against freezing and overheating. The equipment has a piezo spark, and its power is 10 kW. According to consumers, the heated area of ​​the room can reach 100 m2, and the average gas flow per hour is 0.6 m3. This gas boiler "Lemax-Premium" has a range of temperature control in the range from 60 to 90 ° C, but the operating pressure of the heating circuit can vary from 0.2 to 1.9 bar.

The diameter of the chimney is 100 mm, the diameter of the pipeThe gas supply is 1/2 inch. Consumers claim that the dimensions of the device are compact, but if you decide to fit it into the boiler house of your house, it is important to know the exact dimensions, in this model they are 748x330x499 mm.

User's manual

It should be remembered that the installation workshould be carried out by a specialized organization, this includes preventive maintenance. The owner of the boiler can check and clean the chimney, and also repair the water heating system. The Lemax Premium boiler should be used at facilities that are not characterized by hazardous conditions. Do not use the boiler without connecting it to the chimney, before starting work, make sure that the chimney is not blocked. Sufficient traction must be ensured, if it is weak, equipment can not be used. Maintenance is carried out by qualified personnel. The device must not be installed in rooms with aggressive dust and vapors.

Conclusion

It is important not only to correctly choose the boiler brand"Lemax", but also follow the rules of maintenance. They say that it is impossible to inflame equipment not connected to the heating system, as well as to operate it with a malfunctioning automatic system.